BDF36015 PowerPacT B Circuit Breaker, 3 Pole, 15A, 600Y/347VAC
The BDF36015 PowerPacT B Circuit Breaker is a robust and versatile protection device within the Schneider Electric PowerPacT range. This 3-pole, 15 Amp thermal-magnetic circuit breaker is designed for demanding electrical distribution applications in various environments, including industrial and commercial settings.
It features a rated operational voltage of 600Y/347VAC and offers impressive breaking capacities of 14kA at 600Y/347VAC, 18kA at 240VAC, and 25kA at 208Y/120VAC conforming to UL 489 standards. It is also dual-rated for DC networks with a breaking capacity of 14kA at 250VDC (UL 489). For IEC 60947-2 standards, it provides up to 25kA at 220-240VAC and 18kA at 380-415VAC/440VAC. The breaker is equipped with an 80% continuous current rating, making it suitable for a wide range of loads.
The BDF36015 is a unit-mount circuit breaker with integrated DIN rail and back pan mounting capability, offering flexible installation options. It features a toggle control type for easy operation and includes terminal nuts for secure electrical connections. The thermal-magnetic trip unit ensures reliable protection against overloads and short circuits.
This PowerPacT B breaker is designed for enhanced protection, helping to prevent and protect both people and equipment from electrical threats. Its robust construction provides a mechanical durability of 15,000 cycles and an electrical durability of 10,000 cycles at 440V In. The product is highly certified, bearing UL, CSA, NOM, IEC, CCC certifications, and CE marking, affirming its compliance with global safety and quality standards. It also meets HACR rating requirements.
- Product Type: Circuit Breaker
- Manufacturer Part Number (MPN): BDF36015
- Brand/Series: Schneider Electric PowerPacT B
- Poles: 3P (3 protected poles)
- Rated Current (In): 15 A
- Rated Operational Voltage (Ue): 600Y/347 VAC 50/60 Hz, 250 V DC
- Network Frequency: 50/60 HzTrip Unit Technology: Thermal-magnetic (TM-D)
- Breaking Capacity (Icu/AIR):
- 25 kA at 208Y/120 V AC (UL 489)
- 18 kA at 240 V AC (UL 489)
- 25 kA at 480Y/277 V AC (UL 489)
- 14 kA at 480 V AC (UL 489)
- 18 kA at 600Y/347 V AC (UL 489)
- 14 kA at 250 V DC (UL 489)
- 25 kA Icu at 220...240 V AC (IEC 60947-2)
- 18 kA Icu at 380...415 V AC (IEC 60947-2)
- 18 kA Icu at 440 V AC (IEC 60947-2)
- 14 kA Icu at 500...525 V AC (IEC 60947-2)
- Rated Service Breaking Capacity (Ics):
- 25 kA at 220...240 V AC (IEC 60947-2)
- 18 kA at 380...415 V AC (IEC 60947-2)
- 18 kA at 440 V AC (IEC 60947-2)
- 14 kA at 500...525 V AC (IEC 60947-2)
- Rated Insulation Voltage (Ui): 800 V (IEC 60947-2)
- Rated Impulse Withstand Voltage (Uimp): 8 kV (IEC 60947-2)
- Continuous Current Rating: 80 %
- Suitability for Isolation: Yes (IEC 60947-2)
- Utilization Category: Category A
- Mechanical Durability: 15,000 cycles
- Electrical Durability: 10,000 cycles (at 440 V In)
- Mounting Mode: Clip-on (35 mm symmetrical DIN rail), By screws (plate)
- Electrical Connection: Terminal nut (ON and OFF end)
- Tightening Torque:
- 5 N.m (44.3 lbf.in) for 2.5-16 mm² (AWG 14-AWG 4)
- 9 N.m (79.7 lbf.in) for 25-95 mm² (AWG 3-AWG 3/0)
- Wire Stripping Length: 20 mm (0.8 in)
- AWG Gauge Compatibility: AWG 14...AWG 8 (Al/Cu), AWG 6...AWG 3/0 (Al/Cu)
- Dimensions (W x H x D): 81 mm (3.2 in) x 137 mm (5.4 in) x 80 mm (3.1 in)
- Weight: 0.924 kg (2.037 lb)
- Color: Gray (RAL 7016)
- IP Degree of Protection: IP40 (Front cover, IEC 60529)IK Degree of Protection: IK07 (IEC 62262)
- Pollution Degree: 3 (IEC 60947-1)
- Ambient Air Temperature for Operation: -25…70 °C (-13…158 °F)
- Ambient Air Temperature for Storage: -50…85 °C (-58…185 °F)
- Operating Altitude: 2000 m (6561.68 ft) without derating, 5000 m with derating
- Standards: EN/IEC 60947-2, GB 14048.2, UL 489, CSA C22.2 No 5, NEMA AB1, EN/IEC 60947-5-1, NMX J-266
- Product Certifications: UL, IEC, CCC, EAC, CSA, NOM, CE
- HACR Rated: Yes
- Comprehensive Protection: Thermal-magnetic trip unit provides robust protection against overloads and short circuits.
- Multi-Voltage and Multi-Network: Dual-rated for AC (up to 600Y/347V) and DC (up to 250V) applications.
- High Breaking Capacity: Offers high interrupt ratings, including 14kA at 600Y/347VAC (UL 489).
- Flexible Mounting Options: Supports both integrated DIN rail and back pan mounting for ease of installation.
- Global Compliance: UL, CSA, NOM, IEC, CCC certified, and CE marked, ensuring adherence to international standards.
- Durable Construction: Built for long operational life with high mechanical and electrical durability cycles.
- HACR Rated: Suitable for use in Heating, Air Conditioning, and Refrigeration equipment.
- Easy Connections: Features terminal nuts and wide wire stripping length for convenient wiring.